Specifications
Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-8  Handling Alarms  Optimux-106 Ver. 6.1 
Displaying System Alarms 
Monitoring>System>Active Alarms 
 Source Description Severity Status 
1 Local Dev Remote Connection Failed Major Unmasked 
2 Local Dev Redundancy not available Major Unmasked 
> 
ESC-Previous menu; !-Main Menu; &-Exit; ?-Help    1 User(s) 
Figure 
5-8. Active Alarms Screen 
Table 
5-6. Active Alarm Screen Fields 
Field Description 
Source  The source that generated the alarm. Can be one of the following: 
Local Device – system level alarm 
Local LINK <A,B> – alarm generated on local uplink 
Remote LINK <number> – alarm generated on remote uplink 
Local T1 <number> – alarm generated on local T1 port 
Remote T1 <number> – alarm generated on remote T1 port 
Local Ethernet Management – alarm generated on local Ethernet port 
Remote Ethernet Management – alarm generated on remote Ethernet port 
Description  Description of the alarm 
Severity  Indicated the severity of the relevant alarm 
MINOR- Minor alarm 
MAJOR- Major alarm 
Status  Status of the alarm: 
Masked – active alarm for which no trap is sent. 
Unmasked – active alarm for which trap is sent. 
The Optimux-106 system alarms are described in 
Table 
5-8
. 
Configuring Alarms 
You can configure whether various groups of alarms are trapped or not. 
Configuration>System>Alarms
1. Device Number > (Local) 
2. Alarms > (Unmasked) 
3. Remote Connection Failed > (Unmasked) 
> 
Please select item <1 to 3> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
5-9. Alarm Menu 