Specifications
Installation and Operation Manual  Chapter  5 Monitoring and Diagnostics 
Optimux-106 Ver. 6.1  Handling Alarms  5-9 
Table 
5-7. Alarm Configuration Parameters 
Parameter Possible Values Description 
Device Number  Local 
Remote 
Sets whether local or remote 
device is to be masked or 
unmasked 
Alarms Masked 
Unmasked 
Masked – The selected device 
alarms are masked 
Unmasked – The selected 
device alarms are unmasked 
Remote Connection 
Failed 
Masked 
Unmasked 
Masked – The selected remote 
connection alarm are masked 
Unmasked – The selected 
remote connection alarm are 
unmasked 
List of Alarms and Events 
The Optimux-106 alarms are described in 
Table 
5-8
. 
Table 
5-8. Optimux-106 System Alarms 
Code  Message on terminal  Description  Severity 
1  PS A fail  No voltage in power supply A.  Major 
2  PS B fail  No voltage in power supply B.  Major 
3  Remote connection FAIL  A managment connection could not be established with 
the remote device. 
Major 
4 Redundancy not 
available 
Redundancy mode is set to AUTO or MANUAL but the 
second link is not installed. 
Major 
30  ETH Integrity fail  Failure in Ethernet management port 
integrity or in the fast Ethernet integrity. 
ETH-MNG 
ETH 
Major 
31  Signal Loss  Signal loss detected on uplinks or 
channels. 
T1 
Link 
Major 
33  Rx AIS  Received AIS on the uplinks or the 
channels. 
T1 Minor 
The Optimux-106 events are described in 
Table 
5-9
. 
Table 
5-9. Optimux-106 Events 
Code Event  Description 
100  Software process failed  Failed to process software download. 
101  Buffer overflow  The event log buffer exceeded its maximum size and new events are 
written over the old ones. 










