Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-10  Troubleshooting  Optimux-106 Ver. 6.1 
5.4  Troubleshooting 
If a problem occurs, check the displayed indications and refer to 
Section 3-2 
and
Table 3-1 
for their interpretation. 
Identify the trouble symptoms and perform the actions listed under Corrective 
Measures in the order given in 
Table 
5-10
, until the problem is corrected. 
Table 
5-10 Troubleshooting Chart 
Trouble Symptoms  Probable Cause  Corrective Measures 
Optimux-106 does not 
respond 
No power  Check that both ends of the power cable are properly 
connected. If the power cable is properly connected, but the 
power supply still does not respond, then the power supply is 
defective (see below). 
If Optimux-106 is powered from a DC source, check the 
polarity of the power connections. 
Defective Power 
Supply 
Disconnect the power from both ends and replace with 
another power supply. 
Defective 
Optimux-106 
Replace the Optimux-106 unit. 
PWR indicator lights in 
red or yellow 
Defective power 
supply 
Turn the respective power supply off for at least 10 minutes, 
and then turn it on again. 
If the PWR indicator is still red or yellow, have Optimux-106 
repaired as soon as possible. 
The SYNC LOSS indicator 
of the Uplink lights. 
External problem  Activate the local loopback on Optimux-106. Check that the 
SYNC LOSS and AIS indicators of the Uplink in use turn OFF. 
If the indicators turn off, check the T3 interface connections, 
the T3 transmission path to the remote unit, and the remote 
unit. 
Defective 
Optimux-106 
Replace the Optimux-106 unit. 
Defective 
Optimux-106 
Activate the local loopback on Optimux-106. Check that the 
SYNC LOSS and AIS indicators of the Uplink in use turn OFF. If 
one of the indicators remains lit, replace Optimux-106. 
None of the units 
connected to a local 
Optimux-106 receive the 
remote equipment. 
External problem  Activate the local loopback on Optimux-106. Check that all 
the SYNC LOSS and AIS indicators turn OFF, and that the 
equipment connected to the local tributaries receives their 
own transmissions. If the indicators turn OFF, the problem is 
external. Troubleshoot the remote unit, and the uplink 
transmission path. 
Defective 
Optimux-106 
Replace the Optimux-106. 