Installation and Operation Manual  Chapter  5 Monitoring and Diagnostics 
Optimux-106 Ver. 6.1  Performing Diagnostic Tests  5-11 
Trouble Symptoms  Probable Cause  Corrective Measures 
Only one of the units 
connected to a local 
Optimux-106 does not 
receive the remote 
equipment. 
Equipment problem  Check the equipment connected to the local tributary, and its 
cable connections. Check the remote tributary equipment. 
Defective 
Optimux-106 
Activate the uplink local loopback in the local 
Optimux-106. Check that any previously lit alarm indicators 
related to the tributary turns OFF. 
If the indicator turns OFF, the problem is external; if the 
indicators remain lit, replace Optimux-106. 
No menus are available.  Incomplete 
downloading of 
new FLASH version 
Turn Optimux-106 ON and proceed to download the new 
FLASH version again. 
5.5  Performing Diagnostic Tests 
Optimux-106 supports the following types of loopback connections: 
•  Loopback at the local Optimux-106 
•  Loopback towards the remote Optimux-106. 
The test functions are controlled by the management software. The available 
loopback functions are described in the following paragraphs. 
Diagnostics 
Setting Uplink Loopbacks 
Diagnostic loopbacks are configured and monitored using the following menu: 
Optimux-106 
Diagnostics 
1. Device Number > (Local) 
2. Link Loop type > (No Loop) 
3. Link LLB loop timeout (min) [1-255] ... (5) 
4. Channel's Loop [] > 
5. Clear all Channel's loops 
> 
Please select item <1 to 5> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
5-10. Diagnostics Menu 