Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-12  Performing Diagnostic Tests  Optimux-106 Ver. 6.1 
Table 
5-11. Diagnostics Parameters 
Parameter Possible Value Description 
Device Number  Local 
Remote 
Identifies whether 
parameters shown are for 
the local or remote device. 
Link Loop type  No Loop 
LLB 
RLB 
Identifies the type of loop 
set on the uplink port: 
•  LLB – Loopback set on 
local device 
•  RLB – Loopback set on 
remote device. 
Link LLB loop timeout  1 to 255 (test runs for the 
specified number of 
minutes) 
Default: 5 
The duration of the 
loopback test, in minutes. 
This value applies to both 
uplinks and T1 loopback 
tests. 
A value of 0 can only be 
set on the local device. 
Channel's Loops    Displays the T1 Loop 
menu (see 
Figure 
5-11
). 
Clear all Channel's loops    Clears all T1 loops 
³  To run a loopback on an uplink: 
1.  Set Device Number to the device being configured (Local or Remote). 
2.  Set the uplink LLB loop timeout to the number of minutes the loopback must 
run. 
3.  Set uplink Loop type to the type of loop to run on this device (LLB or RLB). 
The loopback test begins running immediately after the loopback is set. 
Setting the Uplink Local Loopback (LLB) in the remote Optimux-106 disconnects 
the link, and as such, is irreversible. To remove this loopback, connect a terminal 
to the remote unit or shut down the power to the remote unit. If you set the 
Uplink LLB timeout on the remote Optimux-106, the loopback test will stop after 
the specified timeout period. 
Setting T1 Channel Loopbacks 
The device being configured is set in the Diagnostics Menu (
Figure 
5-10
). The 
loopback on each port is set via the following screen. 
Cautio
n