Specifications
Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-14  Performing Diagnostic Tests  Optimux-106 Ver. 6.1 
This test checks the operation of the connections to the equipment attached to 
the local tributary interfaces. 
Local Optimux-106
Tr i b u t ar y
Interface
Mux/Demux
Uplink Interface
AIS
~
Tr i b u t ar y
Interface
Tr i b u t ar y
Interface
Tr i b u t ar y
Interface
Figure 
5-12 T1 Local Loopback in Optimux-106 
Each port can be set separately. 
Uplink Local Loopback in the Optimux-106 
The Uplink local loopback returns the transmit signal of the active Uplink interface 
to the input of the receive path. Simultaneously, the local Optimux-106 sends an 
unframed all-ones signal to the uplink. 
Figure 
5-13
 shows the Uplink local loopback connection. 
When this loopback is activated, the equipment connected to the local 
Optimux-106 tributary must receive its own transmission. 
This test checks the operation of the local Optimux-106, and the connections to 
the equipment attached to the tributary interfaces. 










