Specifications
Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-12  Handling Events  Optimux-108 Ver. 6.1 
Table 
5-8. Optimux-108 Alarms 
Code  Terminal Message  Description  Port  Severity 
1  PS A fail  No voltage in power supply A.    Major 
2  PS B fail  No voltage in power supply B.    Major 
3 Remote connection 
FAIL 
A managment connection could not be 
established with the remote device. 
 Major 
4 Redundancy not 
available 
Redundancy mode is set to AUTO or MANUAL 
but the second link is not installed. 
 Major 
30  ETH Integrity fail  Failure in Ethernet management or Ethernet 
user port integrity. 
ETH-MNG 
ETH 
Major 
31  Signal Loss  Signal loss detected on uplinks or channels.  E1 
LINK 
Major 
32  Loss of Frame  Frame loss detected on Uplink    Major 
27  DTE Failure (for V.35 
option only) 
DTE is not ready/connected (identified only if 
ISO 2110 interface is connected to 
Optimux-108). 
V.35 Major 
33  Rx AIS  Received AIS on the channels.  E1  Minor 
Masking Alarms 
You can configure whether various groups of alarms are trapped or not. 
Optimux-108 
Configuration>System>Alarms 
1. Device Number > (Local) 
2. Alarms (Unmasked) 
3. Remote Connection Failed (Unmasked) 
> 
Please select item <1 to 3> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
5-11. Alarm Menu 
Table 
5-9. Alarm Configuration Parameters 
Parameter Possible Values  Description 
Device Number  Local 
Remote 
Sets whether local or remote device is 
to be masked or unmasked 
Alarms Masked 
Unmasked 
Masked – The selected device alarms 
are masked 
Unmasked – The selected device 
alarms are unmasked 