Specifications
Installation and Operation Manual  Chapter  1 Introduction 
Optimux-108 Ver. 6.1  Technical Specifications  1-9 
Management 
Optimux-108 can be configured and monitored locally via an ASCII terminal, or 
remotely via Telnet, Web-based remote access terminal (ConfiguRAD) or  
RADview-TDM running in a Windows or Unix environment. 
Power 
The power supply is a wide-range AC/DC power supply that can be connected to 
either an AC power source (100 to 240 VAC), or to a DC power source 
(–48 VDC). 
Optimux-108 can be ordered with one or two power supplies. When two power 
supplies are installed, they share the load. If one of the power supplies fails or its 
input power is disconnected, the other one continues providing power to the unit. 
1.4  Technical Specifications 
Uplink Interface 
Number of Links 
One or two (A and B) 
Type 
Fiber Optic 
Performance 
Refer to
 Table 
1-1
Connectors 
ST, SC, FC/PC, or SC/PC, ordered option 
(SF1/SF2 options only available with SC) 
(SF3 option only available with SC/APC) 
E1 Tributary 
Interface 
Applicable Standards 
ITU-T Rec. G.703, G.823 
Nominal Line Data Rate 
2048 kbps 
Line Code 
HDB3 
Bit Rate Tolerance 
±25 ppm 
Line Impedance 
120Ω (balanced) or 75Ω (unbalanced) 
Connectors 
Balanced interface: Shielded RJ-45 connector 
Unbalanced interface: two BNC coaxial connectors 
Signal Levels 
Transmit level 
Balanced Interface 
±3V ±10% 
Unbalanced 
Interface 
±2.37V ±10% 