Specifications
Installation and Operation Manual  Chapter  3 Operation 
Optimux-108 Ver. 6.1  Default Settings  3-3 
Table 
3-2. Optimux-108 Rear Panel Indicators 
LED Function  Color  Meaning 
USER ETH: LINK/ACT 
Yellow  On - USER link is up 
Blinking yellow  USER link is up and Rx and/or Tx frames are 
being transmitted 
Yellow  Off – Management link is down 
USER ETH: 100  Green  On – 100M mode 
Off – 10M mode 
MNG ETH: LINK/ACT  Yellow  On - Management link is up 
  Blinking yellow  Management link is up and Rx and/or Tx frames 
are being transmitted 
  Yellow  Off – Management link is down 
MNG. ETH: 100  Green  On – 100M mode 
Off – 10M mode 
SIG (located on the bottom 
of the fiber optic module) 
Green  On – Signal is detected on fiber optic module 
Off – signal not detected 
3.3  Default Settings 
Table 
3-3
 lists the default settings of the Optimux-108 configuration parameters.  
Table 
3-3. Default Settings 
Type Parameter Default Value 
System   
 Device Information 
Name Optimux-108 
Location  The Location of the Device 
Contact Person  Name of Contact Person 
 Host 
IP address  0.0.0.0 
 IP mask 0.0.0.0 
 Default gateway 0.0.0.0 
Read Community  public 
Write Community  private 
Trap Community  public 
 Management Access 
Telnet All 
SNMP  All 
Web  All 










