Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-108 Ver. 6.1  Configuring Optimux-108 for Management  4-5 
Table 
4-1. User Information Fields 
Field Possible 
Values 
Description 
User Name    Name of user defined in the device. 
Access level  RO  Read Only. This user can display information, 
but cannot modify parameters. 
  RW  Read/Write. This user has full control over the 
device and can modify parameters. 
Dynamic/Permanent Permanent 
Dynamic 
Indicates whether this user name is built into 
the system or added by an administrator. 
Built-in users are permanent. 
Configuring Control Port Parameters 
Optimux-108 embedded software enables you to configure the serial port parameters, 
which include specifying terminal baud rate, controlling pop alarms and security 
timeout. 
³  To access the Control Port menu: 
•  From the System Configuration menu, select Control Port. 
The Control Port menu appears (see 
Figure 
4-6
). 
Optimux-108 
Configuration>System>Control Port 
1. Baud rate > (115200 bps) 
2. Security Timeout (10 min.) 
3. Pop Alarms (ON) 
> 
Please select item <1 to 3> 
ESC-Previous menu; !-Main Menu; &-Exit 
Figure 
4-6. Control Port Menu 
³  To configure the control port data rate: 
1.  From the Control Port menu, select Baud Rate. 
The Baud Rate menu appears (see 
Figure 
4-7
). 
2.  Select the terminal rate by typing the number corresponding to the desired 
value, and pressing <Enter>. 
The Baud Rate parameter is masked during Telnet and ConfiguRAD sessions. 
Note 