Specifications
The maximum permissible current capability of the branch distribution circuit that supplies power 
to the product is 16A (20A for USA and Canada). The circuit breaker in the building installation 
should have high breaking capacity and must operate at short-circuit current exceeding 35A (40A 
for USA and Canada). 
Before connecting the DC supply wires, ensure that power is removed from the DC circuit. Locate 
the circuit breaker of the panel board that services the equipment and switch it to the OFF 
position. When connecting the DC supply wires, first connect the ground wire to the 
corresponding terminal, then the positive pole and last the negative pole. Switch the circuit 
breaker back to the ON position. 
A readily accessible disconnect device that is suitably rated and approved should be incorporated 
in the building installation. 
If the DC power supply is floating, the switch must disconnect both poles simultaneously. 
Connecting Data and Telecommunications Cables 
Data and telecommunication interfaces are classified according to their safety status. 
The following table lists the status of several standard interfaces. If the status of a given port 
differs from the standard one, a notice will be given in the manual. 
Ports Safety Status 
V.11, V.28, V.35, V.36, RS-530, X.21, 
10 BaseT, 100 BaseT, Unbalanced E1, 
E2, E3, STM, DS-2, DS-3, S-Interface 
ISDN, Analog voice E&M 
SELV  Safety Extra Low Voltage: 
  Ports which do not present a safety hazard. Usually 
  up to 30 VAC or 60 VDC. 
xDSL (without feeding voltage), 
Balanced E1, T1, Sub E1/T1 
TNV-1 Telecommunication Network Voltage-1: 
  Ports whose normal operating voltage is within the 
  limits of SELV, on which overvoltages from
  telecommunications networks are possible. 
FXS (Foreign Exchange Subscriber)  TNV-2 Telecommunication Network Voltage-2: 
  Ports whose normal operating voltage exceeds the 
  limits of SELV (usually up to 120 VDC or telephone 
  ringing voltages), on which overvoltages from 
  telecommunication networks are not possible. These 
  ports are not permitted to be directly connected to 
  external telephone and data lines. 
FXO (Foreign Exchange Office), xDSL 
(with feeding voltage), U-Interface 
ISDN 
TNV-3 Telecommunication Network Voltage-3: 
  Ports whose normal operating voltage exceeds the 
  limits of SELV (usually up to 120 VDC or telephone 
  ringing voltages), on which overvoltages from 
  telecommunication networks are possible. 
Always connect a given port to a port of the same safety status. If in doubt, seek the assistance 
of a qualified safety engineer. 
Always make sure that the equipment is grounded before connecting telecommunication cables. 
Do not disconnect the ground connection before disconnecting all telecommunications cables. 
Some SELV and non-SELV circuits use the same connectors. Use caution when connecting cables. 
Extra caution should be exercised during thunderstorms. 