Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-108 Ver. 6.1  Configuring Optimux-108 for Operation  4-9 
The System Configuration menu opens. The alarm forwarding option is 
disabled by default. 
Optimux-108 
Configuration>System 
1. Management > 
2. Control Port > 
3. Fault Propagation (Off) 
4. Alarms > 
5. Redundancy > 
6. Factory Default > 
> 
Please select item <1 to 6> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-11. System Configuration Menu 
2.  Type 3 to enable alarm forwarding: 
  When signal loss or sync loss is detected on the uplink, the USER-ETH 
port on both (local and remote products) is shut down. 
  When the USER-ETH port detects that the link is down, the USER-ETH port 
on the remote product is automatically shut down. 
Configuring E1 Channel Parameters 
The following menu is used to configure the E1 ports. 
Optimux-108 
Configuration>Physical Layer>E1 
1. Device Number > (Local) 
2. Port number [1-4] > (1) 
3. Port Name ... () 
4. Alarms > (Unmasked) 
> 
Please select item <1 to 4> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-12. E1 Configuration Screen 
Table 
4-2. E1 Channel Parameters 
Parameter Possible Value  Description 
Device Number  Local 
Remote 
Identifies whether parameters shown are 
for the local or remote device. 
Port number  1 to 4  Identifies the E1 port to configure. 
Port Name  String of up to 15 
characters 
Default: Null 
A name to easily identify this E1 port. 