Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-10  Configuring Optimux-108 for Operation Optimux-108 Ver. 6.1 
Parameter Possible Value  Description 
Alarms Masked 
Unmasked 
Identifies whether alarms triggered by this 
port are masked or not. When masked, 
these alarms are not trapped and are not 
recorded in the log file. 
Configuring Uplink Parameters 
³  To configure uplinks: 
•  From the Main menu, choose Configuration>Physical Layer>Link. 
Optimux-108 
Configuration>Physical Layer>Link 
1. Device Number > (Local) 
2. Port number > (LINK A) 
3. Port Name ... () 
4. Alarms > (Unmasked) 
> 
Please select item <1 to 4> 
ESC-Previous menu; !-Main Menu; &-Exit 1 User(s) 
Figure 
4-13. Link Menu 
Table 
4-3. Uplink Parameters 
Parameter Possible Value  Description 
Device Number  Local 
Remote 
Identifies whether parameters 
shown are for the local or remote 
device. 
Port number  LINK A or LINK B  Identifies the uplink port to 
configure. 
Port Name  String of up to 15 characters 
Default: Null 
A name to easily identify this uplink 
port. 
Alarms Masked 
Unmasked 
Identifies whether alarms triggered 
by this port are masked or not. 
When masked, these alarms are not 
trapped and are not recorded in the 
log file. 
Configuring V.35 Parameters 
The following menu is used to configure parameters of the optional V.35 
interface. 