Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-108 Ver. 6.1  Configuring Optimux-108 for Operation  4-11 
Optimux-108 
Configuration>Physical Layer>V.35 
1. Device Number  > (Local) 
2. Administrative status      (Up) 
3. Port Name  ... () 
4. Clock Source  > (Internal) 
5. DCD Status   >    (Permanent ON) 
6. CTS Status   >    (Permanent ON) 
7. DTE Loop Detection  >    (Disable) 
8. Alarms        (Unmasked) 
> 
Please select item <1 to 8> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
4-14. V.35 Menu 
Table 
4-4. V.35 Parameters 
Parameter Possible Value  Description 
Device Number  Local 
Remote 
Identifies whether parameters 
shown are for the local or remote 
device. 
Administrative 
status 
UP 
Down 
Identifies whether interface is Up or 
Down. In case it is down, all other 
parameters are not displayed 
Port Name  String of up to 15 characters 
Default: Null 
A name to easily identify this uplink 
port. 
Clock Source  Internal 
LBT 
External 
Identifies whether V.35 interface 
clock is internal, LBT (Loop back 
timing) or External 
DCD Status  Permanent ON 
Controll 
Identifies whether DCD (Data Carrier 
Detect) is permanently set to ON or 
it is set to ON only when there is no 
signal failure in the active link. 
CTS Status  Permanent ON 
Controll 
Identifies whether CTS (Clear to 
Send) is permanently set to ON or it 
is set to ON only when RTS (Request 
to Send) is ON. 
DTE Loop 
Detection 
Disable 
Enable 
Identifies whether DTE is able to set 
LLB loop on V.35 interface. 
Disable – LLB loop is not applied. 
Enable – LLB is applied 