Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-12  Configuring Optimux-108 for Operation Optimux-108 Ver. 6.1 
Parameter Possible Value  Description 
Alarms Masked 
Unmasked 
Identifies whether alarms triggered 
by this port are masked or not. 
When masked, these alarms are not 
trapped and are not recorded in the 
log file. 
Configuring Redundancy 
Configuring Local Redundancy 
Optimux-108 
Configuration>System>Redundancy>Local Redundancy 
1. Force Link (LINK A) 
2. Mode > (Auto) 
> 
Please select item <1 to 2> 
ESC-Previous menu; !-Main Menu; &-Exit 
Figure 
4-15. Local Redundancy Menu 
Table 
4-5. Local Redundancy Parameters 
Parameter Possible Values Description 
Force Link  Link A 
Link B 
Sets the active link. 
Mode  Auto  When the selected main link (for example, Link A) 
fails, Optimux-108 automatically switches over to the 
backup Main Link (Link B, in this example). When Link 
A recovers, the active link returns to Link A. 
  Manual  When the selected Force Link fails, the system 
switches to the backup link. The backup link remains 
in use, even if the Force Link returns to service. 
  Off  Turns off redundancy. When the selected Main Link 
fails, Optimux-108 does not change over to the 
backup Main Link. 
You can set the mode for the remote device, which will then perform redundancy 
according to the status of its links. 
Note 