Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-108 Ver. 6.1  Performing Additional Tasks  4-15 
You can monitor the following aspects of the Optimux-108 system: 
•  System up-time 
•  MAC address 
•  Alarms and events 
•  Interface status 
The System Monitoring menu screen is shown in 
Figure 
4-18
. 
Table 
4-6
 explains 
the System Monitoring parameters. 
Optimux-108 
Monitoring>System 
 MAC Address (0020D222E15F) 
 Sys Up Time ... (0 days 05:06:34) 
1. Active Alarms [] 
2. Event Log [] 
3. Status > 
4. Interface Status [] 
5. Clear Log File 
> 
Please select item <1 to 5> 
ESC-Previous menu; !-Main Menu; &-Exit        1 User(s) 
Figure 
4-19. Monitoring Menu 
Table 
4-6. System Monitoring Parameters 
Parameter Description 
MAC Address  The address the device holds when transmitting frames 
via the Ethernet port. 
Sys Up Time  Elapsed time since system was powered up. 
Active Alarms  Displays active alarms on a local and remote devices, 
their severity (Major or Minor) and status (Masked or 
Unmasked). For description of Active Alarms screen, refer 
to 
Chapter 6
. 
Event Log  Displays the events logged by the system. Displays the 
source of the event, alarm indicated as the result of the 
event, its status (ON, OFF, NA) and severity (Major, Minor 
or Event). It can be maximum 200 entries to the log file. 
For description of Event Log screen, refer to 
Chapter 6
. 
Status  Displays the detailed system status 
Interface Status  Displays the current interface status (UP, DOWN, NA), 
type and speed for all the interfaces 
Clear Log File  Clears the log file 