Specifications
Installation and Operation Manual  Chapter  5 Monitoring and Diagnostics 
Optimux-108 Ver. 6.1  Monitoring Performance  5-3 
Table 
5-2. System Status Parameters 
Parameter Description 
Device Number 
Indicates the Optimux-108 currently being monitored: 
•  Local 
•  Remote 
Device type  Displays the device type 
Redundancy status  Indicates if redundancy is available or not available 
•  Available – two uplinks are mounted 
•  Not Available – only one uplink is mounted or Redundancy 
mode is ‘OFF’ 
Redundancy mode  The redundancy state of the system: 
•  AUTO 
•  MANUAL 
•  OFF 
The option is hidden when redundancy status is not available. 
Force Link  Indicates the main uplink 
Active Link  Identifies the currently active link 
PS A Status  The state of the Power Supply A: 
•  OK 
•  Fault 
PS B Status  The state of the Power Supply B: 
•  OK 
•  Fault 
Alarm Indication  Current system status: 
•  Normal - System is functioning normally; no alarms activated 
•  Major - One or more major alarms are currently activated 
•  Minor - One or more minor alarms are currently activated 
Test Indication  Indicates whether any tests are currently active in the device: 
•  ON - Tests are currently active in the device 
•  OFF - No tests are currently running 
³  To set the device to monitor: 
•  Enter 1. 
The Device Number toggles between Local and Remote, to indicate the 
device currently being monitored. 