Specifications
Chapter  5 Monitoring and Diagnostics  Installation and Operation Manual 
5-10  Handling Events  Optimux-108 Ver. 6.1 
 Optimux-108 
Monitoring>System>Event Log 
 Source Alarm Status Severity 
 1 Local Device Remote connection fail ON MAJOR 
 2 Local Device PS B fail ON MAJOR 
| 3 Local MNG-ETH ETH Integrity fail ON MAJOR 
v 4 Local USER-ETH ETH Integrity fail ON MAJOR 
 5 Local Device Redundancy not available ON MAJOR 
 6 Local Ch-1 Signal Loss ON MAJOR 
 7 Local Ch-2 Signal Loss ON MAJOR 
 8 Local Ch-3 Signal Loss ON MAJOR 
 9 Local Ch-4 Signal Loss ON MAJOR 
 10 Local Device Remote connection fail OFF MAJOR 
 ->> 
ESC-prev.menu; !-main menu; &-exit; ?-help 1 Mngr/s 
Figure 
5-9. Event Log 
The log displays the source of the event, alarm indicated as the result of the 
event, its status (ON, OFF, NA) and severity (Major Alarm, Minor Alarm or Event). 
The Optimux-108 events are described in 
Table 
5-7
. 
Table 
5-7. Optimux-108 Events 
Code Event Description 
100  Software process failed  Failed to process software download. 
101  Buffer overflow  The event log buffer exceeded its maximum 
size and new events are written over the old 
ones. 
102  Local login  Login was performed to the PUT. 
103  Invalid Login  Login to the PUT with wrong user name or 
password. 
104  SNMP authentication failure  Read/write via SNMP with wrong community 
105  Cold Start  Power up event 
106  Link Switch  Switch between Link A to Link B 
Clearing Events 
³  To clear the event log: 
1.  From the System Log menu, select Clear Log File. 
A confirmation message appears. 
2.  Enter Yes to clear the event log buffer. 










