Specifications
Optimux-34 Ver. 2.81  Connecting the Interface Cables  1 
Quick Start Guide 
If you are already familiar with the Optimux-34, use this guide to prepare the unit 
for operation. 
1.  Connecting the Interface Cables 
Connecting the Tributary E1 Interfaces 
³  To connect the balanced E1 interface (RJ-45 connector) 
•  Connect the RJ-45 connector of the cable to the E1 port. 
³  To connect the unbalanced E1 interface (BNC connectors) 
1.  Connect the transmit cable to the coaxial connector of the E1 port marked IN. 
2.  Connect the receive cable to the coaxial connector of the E1 port marked 
OUT. 
Connecting the V.35 Interface 
³  To connect the V.35 interface (Smart serial connector) 
•  Connect the V.35 cable supplied with the product to the V.35 interface smart 
serial connector. 
Connecting the Uplink 
³  To connect the uplink: 
1.  Clean the optical connectors using an approved solvent, and dry thoroughly 
using optical tissue. 
2.  Connect to the two optical connectors designated TX (transmit output) and 
RX (receive input) of the appropriate interface. 
3.  Pay attention to correct connection of the transmit and receive cables to the 
corresponding connectors. Avoid sharp bends and twisting of the fiber-optic 
cables. 
For WDM option, only one fiber optic cable per link should be connected. 
Note 