Specifications
Installation and Operation Manual  Chapter  1 Introduction 
Optimux-34 Ver. 2.81  Technical Specifications  1-9 
Figure 
1-8. External and Loopback Timing 
Power Requirements 
Optimux-34 has a hot-swappable, wide range, universal power supply for AC and 
DC options. 
A second power supply is optionally installed in the Optimux-34 to assure 
continuous operation in case of supply failure. When the two supplies are turned 
ON, they share the power consumption of the unit. If one of the power supplies 
fails, the other provides the full power consumption. 
1.4  Technical Specifications 
Electrical Link 
Interface (E3) 
Electrical Interface 
According to ITU-T Rec. G.751 
Jitter 
According to ITU-T Rec. G.823 
Data Rate 
34,368 kbps 
Line Code 
HDB3 
Impedance 
75Ω unbalanced 
Range 
According to ITU-T Rec. G.703 
Connectors (2) 
SMB-BNC 
Redundancy 
Additional electrical link is optional 