Specifications
Installation and Operation Manual  Chapter  1 Introduction 
Optimux-34 Ver. 2.81  Technical Specifications  1-11 
User Ethernet Port 
Physical Interface 
10/100BaseT 
Data Rate 
10/100 Mbps 
Transmission Mode 
•  Full/half-duplex 
•  Autonegotiation enable/disable 
•  Multicast frames enable/disable 
•  Flow Control and Backpressure enable/disable 
Bridge Parameters 
•  Data transfer rate: up to 32 Mbps maximum 
•  2K supported addresses 
•  Supported frame size: up to 1536 bytes 
•  Throughput: up to 60,386 pps (32 Mbps 
data transfer rate, 64-byte frames) 
•  Latency: 30 μsec (32 Mbps data transfer 
rate, 64-byte frames) 
•  Compatible with IEEE 802.3, 802.3x, 802.3u, 
802.1p and 802.1q (802.1D relevant parts) 
•  Fault propagation in LAN in case of WAN 
error (optional) 
•  Connector: RJ-45 
Power 
Number of Supplies 
One or two (power sharing) 
Power Supply 
100-240 VAC, 0.25A 
or 
-48 VDC, 0.35A 
Power Consumption 
AC: 32 VA max 
DC: 13W max 
Unit Indications 
and Alarms 
Unit Indications 
See 
Table 3-1.
Dry Contacts 
•  Maximum Ratings: 1A, 60 VDC, 30 VAC 
•  Major alarms: Power off; E1 loss of signal; E3 
loss of frame on the active link; E3 loss of 
signal on the main link; E3 loss of signal on 
the backup link in Automatic/Manual 
redundancy mode; backup link does not 
install in Automatic/Manual redundancy mode.
In redundant power supply mode: one power 
supply is faulty; self-test fail. 
•  Minor alarm: Power off, AIS on E1 input line, 
AIS on link input 
•  Connector: 9-pin D-type female 