Specifications
Installation and Operation Manual  Chapter  2 Installation and Setup 
Optimux-34 Ver. 2.81  20B19BConnecting to Optimux-34  2-3 
Table 
2-1. List of Optimux-34 Modules 
Module Designation  Fixed/ 
Optional 
Location  Used to provide 
E3 unbalance (coax) Link  Optional  Front slots LINK A/B  Unbalanced interface to the link. 
E3 fiber optic Link  Optional  Front slots LINK A/B  Fiber optic interface to the link. 
Power supply–PWR-A  Optional  On the front side  Optimux-34 supply voltages 
Power supply–PWR-B  Optional  On the front side  Power supply redundancy - power 
consumption sharing or full consumption in 
case of power supply A failure. 
If the 16 E1 unbalanced interface option is needed, order the 2U Optimux-34. 
If there is not enough space for the 2U-high device, the 1U device can be used 
with the RJ-45 to BNC adapter cable (CBL-RJ45/2BNC/E1/X) and 2 BNC cables for 
each channel. 
2.6  Connecting to Optimux-34 
The E1, USER Ethernet, MNG Ethernet, V.35 interface, alarm, power supplies, 
tributary and link connectors are all located on the front panel of the unit as 
shown in the following figures. Front panel LEDs indicate system and link status. 
The management, alarm, and link connectors are detailed in 
Table 
2-2
. 
The rear panel of the Optimux-34 unit is blank. All connectors are located on the 
front panel. 
Figure 
2-1. Typical 1U-high Front Panel with Optional Alarm and V.35 Connectors 
Figure 
2-2. Typical 2U-high Front Panel with Optional Alarm and V.35 Connectors 
Note 