Specifications
Chapter  3 Operation  Installation and Operation Manual 
3-2  Optimux-34 Controls and Indicators  Optimux-34 Ver. 2.81 
Figure 
3-2. Typical 2U-high Front Panel with Optional Alarm and V.35 Connectors 
Table 
3-1. Optimux-34 Front Panel Controls and Indicators 
Name Type State  Function 
PS A  Indicator  OFF  Indicates that the unit is not powered 
ON (green)  Indicates that power supply A is ON and operates normally 
ON (red)  Indicates that a malfunction was detected in PS A or it is not 
powered on. If PS B is installed Optimux-34 will continue to 
operate normally. 
PS B  Indicator  OFF  Indicates that the unit is not powered 
ON (green)  Indicates that power supply B is ON and operates normally 
ON (red)  Indicates that a malfunction was detected in PS B or it is not 
powered on. If PS A is installed Optimux-34 will continue to 
operate normally. 
SYSTEM TST  Indicator  ON (yellow)  Indicates that the system is on loop test. 
    Blinking (yellow)  Indicates that the system is during Auto baud detect process. 
SYSTEM FLT  Indicator  ON (red)  Indicates a control system fault or a failure detected during the 
turn ON self test. 
LINK A SYNC LOSS Indicator  ON (red)  Indicates that a loss-of-signal has been detected on the main 
link. 
    Blinking (red)  Indicates that in Manual Redundancy mode, LINK A is the main 
link and is available but the signal is received from the backup 
link (LINK B) 
LINK A AIS  Indicator  ON (yellow)  Indicates that an alarm indication signaling has been detected 
on the link 
LINK B SYNC LOSS  Indicator  ON (red)  Indicates that a loss-of-signal has been detected on the backup 
link 
    Blinking (red)  Indicates that in Manual Redundancy mode LINK B is the main 
link and is available but the signal is received from the backup 
link (LINK A) 
LINK B AIS  Indicator  ON (yellow)  Indicates that an alarm indication signaling has been detected 
on the backup link 