Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-34 Ver. 2.81  Configuring Optimux-34 for Operation  4-3 
Optimux-34 
Configuration>System>Clock Source 
 1. Local Source > (Internal) 
 2. Remote Source > (Loopback Timing) 
> 
Please select item <1 to 2> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-2. Clock Source Menu 
Table 
4-2
 describes the Local and Remote Source fields in the Clock Source menu 
(see 
Figure 
4-2
). 
Table 
4-2. Clock Source Values 
Field Description  Possible Values  Visibility 
Local Source  Local device clock souce 
Internal 
Loopback Timing 
Always 
Remote Source  Remote device clock souce 
Internal  
Loopback Timing 
When connected to a 
remote device 
• 
The Remote Source option is available only when the Optimux-34 is connected 
to a remote device. 
• 
After resetting to the default values, the clock configuration is INTERNAL. 
2.  From the Clock Source menu, choose either Local Source or Remote Source. 
The Local Source menu is displayed. 
Optimux-34 
Configuration>System>Clock Source>Local Source (Internal) 
 1. Internal 
 2. Loopback Timing 
> 
Please select item <1 to 2> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-3. Local Source Menu 
3.  Choose either Internal timing or Loopback Timing). 
Setting the Device Information 
Each Optimux-34 unit can be configured to retain information about the unit, 
such as its location and a name to easily identify the unit on the network. 
Notes 