Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-34 Ver. 2.81  Configuring Optimux-34 for Operation  4-9 
The Control Port menu is displayed. 
Configuration>System>Control Port
 1. Baud Rate > (115200bps) 
 2. Security Timeout > (10min) 
 3. Pop Alarms > (OFF) 
> 
Please select item <1 to 3> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-9. Control Port Menu 
Table 
4-8
 describes the Baud Rate, Security Timeout and Pop Alarms fields in the 
Control Port menu (see 
Figure 
4-9
). 
Table 
4-8. Control Port Values 
Field Description  Possible Values  Visibility 
Baud Rate  Terminal baud rate  9600 bps 
19200 bps 
38400 bps 
57600 bps 
115200 bps 
Always 
Security 
Timeout 
Gives an indication to exit the terminal after 10 
minutes when a key is not pressed 
Off 
10 min 
Always 
Pop Alarms  Displays the changes in the alarms on the lower 
part of the terminal screen 
On 
Off 
Always 
2.  From the Control Port menu, select Baud Rate. 
The Baud Rate menu is displayed. 
Configuration>System>Control Port>Baud Rate (115200 bps)
 1. 9600 bps 
 2. 19200 bps 
 3. 38400 bps 
 4. 57600 bps 
 5. 115200 bps 
> 
Please select item <1 to 5> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-10. Baud Rate Menu 
3.  Choose the baud rate that matches your management terminal device. 










