Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-34 Ver. 2.81  Configuring Optimux-34 for Operation  4-11 
The Alarms menu is displayed. 
Configuration>System>Alarms
 1. Device Number > (Local) 
 2. Alarms > (Unmasked) 
 3. Remote connection fail > (Unmasked) 
> 
Please select item <1 to 3> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-11. Alarms Menu 
Table 
4-9
 describes the Local and Remote Alarm fields in the Alarms menu (see 
Figure 
4-11
). 
Table 
4-9. Alarms Values 
Field Description  Possible Values  Visibility 
Alarms  Masks or Unmasks the local/remote system alarms. 
It prevents setting the alarms in the log file so no 
trap is sent for these alarms and the dry contact will 
not be activated. 
Masked 
Unmasked 
Always 
Remote 
connection fail 
Masks or Unmasks the remote connection fail 
diagnostic. 
Masked 
Unmasked 
Always 
2.  From the Alarms menu, select Alarms to mask or unmask the local or remote 
alarm. 
Configuring Redundancy between the Local and Remote Devices 
When the redundant link is installed and the redundancy mode is set to 
AUTOMATIC, Optimux-34 starts using the main link. It automatically switches to 
the backup link when the selected main link fails (signal loss/sync loss). The LINK 
A/B SYNC LOSS LED on the front panel indicates the deactivated link. 
Optimux-34 switches back to the main link, when the signal is recovered. 
When the redundant link is installed and the redundancy mode is MANUAL, 
Optimux-34 starts using the main link. It automatically switches to the backup link 
when the main link fails (signal loss/sync loss). The LINK A/B SYNC LOSS LED on 
the front panel indicates the deactivated link. The backup link remains active even 
when the main link recovers. Switching back to the main link is performed by 
setting the redundancy mode to AUTOMATIC from the terminal or by turning the 
system OFF and then ON. 
When the management link-redundancy is OFF, the redundancy function is not 
available. 
³  To configure the uplink redundancy mode for the local and remote devices: 
•  From the System menu, choose Redundancy. 