Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-12 Configuring Optimux-34 for Operation  Optimux-34 Ver. 2.81 
The Redundancy menu is displayed. 
The Remote Redundancy option is available only when the Optimux-34 is 
connected to a remote device. 
³  To configure redundancy on the Optimux-34 or the active link: 
1.  From the Redundancy menu, select Local/Remote Redundancy. 
The Local Redundancy menu is displayed. 
Configuration>System>Local Redundancy
 1. Force Link > (LINK A) 
 2. Mode > (AUTO) 
> 
Please select item <1 to 2> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-12. Local Redundancy Menu 
Table 
4-10
 describes the Force Link and Mode fields in the Local/Remote 
Redundancy menu (see 
Figure 
4-12
). 
Table 
4-10. Local/Remote Redundancy Values 
Field Description  Possible Values  Visibility 
Force Link  The active link 
LINK A 
LINK B 
Always 
Mode  The redundancy mode 
Auto 
Manual 
Off 
Always 
2.  Select Force Link to select Link A or Link B as the main link. 
3.  From the Local/Remote Redundancy menu, select Mode. 
The Mode menu is displayed. 
Configuration>System>Local Redundancy>Mode (AUTO)
 1. AUTO 
 2. MANUAL 
 3. OFF 
> 
Please select item <1 to 3> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-13. Redundancy Mode Menu 
Note 










