4.  Choose the redundancy mode you want to use: Auto, Manual or Off (refer to 
Chapter 3 
for details). 
Configuring the Physical Ports 
Configuring the Ethernet User Port 
³  To configure the Ethernet User port: 
1.  From the Ethernet menu (
Figure 
4-1
), select Port Number. 
The Port Number menu opens. 
2.  From the Port Number Menu, choose USER-ETH. 
The Ethernet User menu appears. 
Configuration>Physical Layer>Ethernet
 1. Device Number > (Local) 
 2. Port Number > (USER-ETH) 
 3. Administrative Status (Up) 
 4. Port Name ...() 
 5. Auto Negotiation > (Enable) 
 6. Flow Control > (Enable) 
 7. Rate Limit > (0 Mbps) 
 8. Alarms > (Unmasked) 
> 
Please select item <1 to 8> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-14. Ethernet User Menu 
Table 
4-11
 describes the fields in the Ethernet User menu. 
Table 
4-11. Ethernet User Values 
Field Description  Possible Values  Visibility 
Device Number  The device value  Local 
Remote 
Always 
Port Number  The Fast Ethernet port number  MNG-ETH 
USER-ETH 
Always 
Administrative Status  Port status  Up 
Down 
Always 
Port Name  User chosen    Always 
Autonegotiation Enables Autonegotiation  Enabled (1)  
Disabled (2) 
Always 
Flow Control  Configures the default administrative 
PAUSE mode for this interface. 
Disabled 
Enabled 
Always 