Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-34 Ver. 2.81  Configuring Optimux-34 for Operation  4-15 
Configuration>Physical Layer>E3 
 1. Device Number > (Local) 
 2. Port Number (LINK A) 
 3. Port Name  ... () 
 4. Alarms   (Unmasked) 
> 
Please select item <1 to 4> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-16. E3 Menu 
Table 
4-12
 describes the Local and Remote Uplink menu (see 
Figure 
4-16
). 
Table 
4-12. E3 Values 
Field Description  Possible Values  Visibility 
Device Number  The device number  Remote 
Local  
Always 
Port Number  E3 port number 
LINK B 
LINK A 
Always 
Port Name  Sets a name for the port containing up to 
15 characters. 
Alarms Masks UpLink alarms 
Masked 
Unmasked 
Always 
2.  Select Device Number option and set the device to either Local or Remote. 
3.  Select Port Number to set the E3 port number to either LINK A or LINK B. 
4.  Select Port Name to set a name for the port. 
5.  Select Alarms to mask or unmask the Uplink alarms. 
Configuring the E1 Port 
The E1 option in the Physical Layer menu is for the configuration of the E1 ports. 
³  To configure the E1 port: 
1.  From the Configuration menu, select Physical Layer> E1.  
The E1 menu is displayed. 