Specifications
Chapter  4 Configuration  Installation and Operation Manual 
4-16 Configuring Optimux-34 for Operation  Optimux-34 Ver. 2.81 
Configuration>Physical Layer>E1 
 1. Device Number > (Local) 
 2. Port Number[1-16] ... (1) 
 3. Administrative Status (Up) 
 4. Port Name  ... () 
 5. Interface Type (Balance (120ohm)) 
 6. Alarms (Unmasked) 
> 
Please select item <1 to 6> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-17. E1 Menu 
Table 
4-13
 describes the E1 fields in the menu (see 
Figure 
4-17
). 
Table 
4-13. E1 Values 
Field Description  Possible Values  Visibility 
Device Number  The device number  Remote 
Local  
Always 
Port Number  E1 port number  1 to 16  Always 
Administrative Status  Port status 
Up 
Down 
Always 
Port Name  Sets a name for the port containing up to 
15 characters. 
 Administrative 
Status (Up) 
Interface Type  Configures the interface to balance or 
unbalance 
Unbalance (75Ω) 
Balance (120Ω) 
Administrative 
Status (Up) 
Alarms  Masks Tributary alarms 
Masked 
Unmasked 
Administrative 
Status (Up) 
2.  Select the Device Number option to set the device to either Local or Remote. 
3.  Select Port Number to set the E1 port number. 
4.  Select Administrative Status and set the status to either Up or Down. 
5.  Select Port Name to set a name for the port. 
6.  Select Interface Type and set to either Balance (120Ω) or Unbalance (75Ω). 
Configure the channels in groups of eight only: Channels 1-8 or 9-16 only. 
7.  Select Alarms to mask or unmask the E1 alarms. 
Configuring the V.35 Port 
The V.35 option in the Physical Layer menu is for the configuration of the V.35 
ports. 