Specifications
Installation and Operation Manual  Chapter  4 Configuration 
Optimux-34 Ver. 2.81  Configuring Optimux-34 for Operation  4-17 
³  To configure the V.35 port: 
1.  From the Configuration menu, select Physical Layer> V.35. 
The V.35 menu is displayed. 
Configuration>Physical Layer>V.35
 1. Device Number > (Local) 
 2. Administrative Status (Up) 
 3. Port name ... () 
 4. Clock Source > (Internal) 
 5. DCD Status > (Permanent ON) 
 6. CTS Status > (Permanent ON) 
 7. DTE Loop Detection > (Disable) 
 8. Alarms (Unmasked) 
> 
Please select item <1 to 8> 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
4-18. V.35 Menu 
Table 
4-14
 describes the V.35 fields in the menu (see 
Figure 
4-18
). 
Table 
4-14. V.35 Values 
Field Description  Possible Values  Visibility 
Device Number  The device number  Remote 
Local  
Always 
Administrative 
Status 
Port status  Up 
Down 
Always 
Port Name  Sets a name for the port containing up to 15 
characters. 
 Administrative 
Status (Up) 
Clock Source  Configures the interface Clock Source 
Internal 
LBT 
External 
Administrative 
Status (Up) 
DCD Status  Configures the interface DCD Status
When set to CONTROL, the DCD signal is set to 
ON when the active link is good (no signal loss, 
frame loss or AIS) 
Permanent ON 
Control 
Administrative 
Status (Up) 
CTS Status  Configures the interface CTS Status
When set to CONTROL, the CTS signal is set ON 
when RTS is ON. 
Permanent ON  
Control 
Administrative 
Status (Up) 
DTE Loop 
Detection 
Configures the interface DTE Loop Detection 
When set to Enable, loops originated by DTE are 
enabled. 
Enable 
Disable 
Administrative 
Status (Up) 