Specifications
Installation and Operation Manual  Chapter  5 Monitoring and Diagnostics 
Optimux-34 Ver. 2.81  Monitoring Performance  5-3 
Monitoring>System>Event Log 
 Source Alarm Status Severity 
 1 LOC device PS A FAIL ON MAJOR 
 2 LOC MNG-ETH Integrity Loss ON MAJOR 
| 3 LOC device Redundancy not available ON MAJOR 
V 4 LOC port 1 Signal Loss ON MAJOR 
 5 LOC port 2 Signal Loss ON MAJOR 
 6 LOC port 3 Signal Loss ON MAJOR 
 7 LOC port 4 Signal Loss ON MAJOR 
 8 LOC port 6 Signal Loss ON MAJOR 
 9 LOC port 7 Signal Loss ON MAJOR 
 10 LOC port 8 Signal Loss ON MAJOR 
 ->> 
> 
ESC-prev.menu; !-main menu; &-exit; ?-help 1 user(s) 
Figure 
5-3. Event Log Screen 
There can be up to 200 entries stored in the log file. 
System Status 
³  To view the system status: 
•  From the System menu, select Status. 
The Status screen is displayed. 
Monitoring>System>Status
 1. Device Number > (Local) 
 Device Type > (Optimux-34) 
 Force Link > (LINK A) 
 Active Link > (LINK A) 
 Redundancy mode > (AUTO) 
 Redundancy status > (Available) 
 Clock source > (Internal) 
 PS A Status > (OK) 
 PS B Status > (Not mounted) 
 Alarm indication > (Major) 
 Test indication > (Off) 
ESC-prev.menu; !-main menu; &-exit 1 user(s) 
Figure 
5-4. Status Screen 
•  Device Number - The Optimux-34 device number. The number is configurable 
if connected to a remote device and not configurable when Optimux-34 is not 
connected to a remote device or when the remote device is not an Optimux 
device. The device number is always visible with one of the following values: 
  Local (default) 
  Remote. 