Specifications
Chapter  6 Software Upgrade  Installation and Operation Manual 
6-2  Upgrading Optimux-34 Software via the File Utilities Menu  Optimux-34 Ver. 2.81 
6.4  Prerequisites 
This section details the Optimux-34 software and versions compatible with the 
new version. It also lists the software file names and outlines system 
requirements needed for the upgrade procedure. 
Software Files 
The new version releases are distributed as software files named OP-34.img. The 
files can be obtained from the local RAD business partner from whom the device 
was purchased. 
System Requirements 
Before starting the upgrade, verify that you have the following: 
•  For upgrade via TFTP: 
  Operational Optimux-34 unit with valid IP parameters configured for the 
host 
  Connection to a PC with a TFTP server application (such as 3Cdaemon or 
PumpKIN), and a valid IP address 
  Software file (OP-34.img) stored on the PC 
•  For upgrade via XMODEM: 
  Operational Optimux-34 unit 
  Connection to a PC with a terminal emulation application (such as 
HyperTerminal) 
  Software file (OP-34.img) stored on the PC. 
6.5  Upgrading Optimux-34 Software via the File 
Utilities Menu 
The recommended software downloading method is downloading by means of 
the TFTP, using the 
Download/upload using TFTP
 menu reached from the File 
Utilities menu. 
Network administrators can use this procedure to distribute new software 
releases to all the managed Optimux-34 units in the network from a central 
location. 
Use the following procedure to download the new software release to 
Optimux-34 via the File Utilities menu. 
1.  Verify that the (OP-34.img) is stored on the PC with the TFTP server 
application. 
2.  Verify that the Optimux-34 host has valid IP parameters. 
3.  Ping the PC to verify the connection. 