Specifications
Chapter 2 Installation and Setup  Optimux-XLT1 Installation and Operation Manual 
2-10 Interfaces and Connections
ELECTRICAL SHOCK HAZARD: Access to the inside of the equipment is 
permitted only to qualified and authorized service personnel. 
Before disconnecting the unit from its cables, verify that the remote unit is 
turned OFF. Disconnect the unit from the power line and from all the cables 
before removing the cover. 
Dangerous high voltages are present inside the Optimux-XLT1 when it is 
connected to power. Moreover, under external fault conditions, dangerous 
high voltages may appear on the lines connected to the Optimux-XLT1. 
Capacitors inside the instruments may still be charged even after the unit has 
been disconnected from the supply source. 
Any setting, or repair of the open unit under voltage should be avoided as 
much as possible and, when inevitable, would be carried out only by a skilled 
technician who is aware of the hazard involved. 
The Optimux-XLT1 contains components sensitive to electrostatic discharge (ESD). 
To prevent ESD damage, avoid touching the internal components. Before moving 
jumpers, touch the Optimux-XLT1 frame. 
Table 2-3. Connectors 
Section  Channel Module  Connector  Used to connect 
A  None  RJ-45  The fixed Ethernet port to a LAN 
B, C, D  ETH/10BaseT  RJ-45  Up to three additional Ethernet ports to LANs 
B, C, D  FETH/10/100BaseT  RJ-45  Up to three additional Ethernet ports to LANs 
B, C, D  4T1/BAL  RJ-45x4  Four T1 balanced channels 
B, C, D  2T1/BAL  RJ-45x2  Two T1 balanced channels 
B, C, D  4 HS  SCSI 26-pin  Four DTE channels 
The rear panel of the Optimux-XLT1 unit (see Figure 2-7), contains the power, 
management, alarm and link connectors as indicated in Table 2-4. 
ALARMS
CONTROL/MNG
ALARMS MANAGEMENT
MNG-ETH
OK
LINK B (BACKUP)
OK
RX TX
POWER A
CAUTION: 
FOR CONTINUED
PROTECTION AGAINST RISK OF
FI RE , RE P LA CE O N L Y W I TH S A ME
TY P E A ND R AT I NG  O F FU SE .
AC POWER
MAIN LINK BACKUP LINK
--
O
--
O
POWER B
DC POWER
VDC-IN
-480
LINK A (MAIN)
OK
RX TX
Figure 2-7. Rear Panel Connections Optimux-XLT1 with Dual Link and Dual Power Supply 