Specifications
Chapter 4 Supervisory Port Software Configuration  Optimux-XLT1 Installation and Operation Manual 
4-6  The Optimux-XLT1 Device Information
Setting Link-Redundancy 
➤  To change the link-redundancy setting: 
1. Type 3 in the Device Information Menu screen. 
The Change Link Redundancy screen appears. 
LOCAL DEVICE 
    CHANGE LINK REDUNDANCY 
 ---------------------- 
 0. Exit. 
 1. Redundancy status AVAILABLE 
 2. Redundancy setup MANUAL 
  Enter your choice: 
2. Type 2 to enter the redundancy setup. 
3. Type 1 for AUTOMATIC, 2 for MANUAL, 3 for OFF, or press ESC to cancel 
your choice. 
4.  To exit to the screen, type 0. 
1.  Redundancy status is not available for changes, but you can change 
Redundancy status even if the status is "NOT AVAILABLE". (And in that case your 
change will take place once the status "AVAILABLE"). 
2.  When in normal operation, the link redundancy setting must be changed only 
after the system has been operating and synchronized for 120 sec on the same 
link. 
3.  Changes to the link redundancy mode take affect up to 120 seconds after being 
made. 
4.  Before synchronizing two Optimux-XLT1 units, the link redundancy mode of 
both units must be the same. 
Notes 