Chapter 4 Supervisory Port Software Configuration  Optimux-XLT1 Installation and Operation Manual 
4-10  The Optimux-XLT1 Interface
The tributaries and fiber optic settings can be set from the terminal (see Changing 
the Configuration of the Interface on page 4-10). The applicable tributaries and 
fiber optic interface states are indicated in Table 4-3. 
Table 4-3. T1 and Fiber Optic Interface States 
State Indicates 
No loop  No loop is set 
Local loop  A local loop is set. An T1 local loop applies to all ports of an T1 module (see 
Troubleshooting Instructions on page 5-3 for details) 
Remote loop  A remote loop is set. A T1 remote loop applies to a single port of a T1 module (see 
Troubleshooting Instructions on page 5-3 for details). Remote loop on fiber optic link is 
not available. 
The Ethernet port is set from a DIP switch. The applicable settings are: 
Table 4-4. Ethernet Setting 
Setting Indicates 
Half duplex  Ethernet port operates in half duplex 
Full duplex  Ethernet port operates in full duplex 
Changing the Configuration of the Interface 
➤  To change the configuration of the monitor interface: 
4. Type 3 in the Interface Menu screen. 
The Change Interface Configuration screen appears. 
LOCAL DEVICE 
  CHANGE INTERFACE CONFIGURATION 
 ------------------------------ 
  NOTE:  To change the configuration of the interface, select it 
    in the next format: 
    - decimal number from 1 to 5 for modules, 
    (1 for module A, 2 for module B,..., 5 for E3 link) 
    - decimal number from 1 to 4 for ports 
    - for E3 link port=1 selects main link, port=2 selects backup link. 
 0. Exit 
 1. Module  module A 
 2. Port  port 1 
  3.  Test Configuration  Filter enabled 
Enter your choice: 