Specifications
Chapter 4 Supervisory Port Software Configuration  Optimux-XLT1 Installation and Operation Manual 
4-20  The Optimux-XLT1 Interface
Changing the Configuration of the Serial Port 
➤  To change the configuration of the serial port: 
1. Type 4 in the Interface Menu screen. 
The Serial Port Configuration screen appears. 
LOCAL DEVICE 
    SERIAL PORT CONFIGURATION 
 ------------------------- 
 0. Exit. 
  1.  Baud rate.  38400 baud 
 2. parity. NO 
  Enter your choice: 
2. Type 1 to set the baud rate 
3. Type 4 for 9600, 6 for 19200, 7 for 38400, 8 for 57600, or 9 for 115200 bps. 
4. Type 2 to set the parity 
5. Type 0 for no parity, 1 for even, or 2 for odd. 
6.  Confirm the action. 
7. Type 0 to exit the Serial Port Configuration screen. 
Resetting to the Default Configuration 
➤  To reset all T1 and fiber optic interfaces to "Normal" operation: 
1. Type 5 in the Interface Menu screen. 
The Set Configuration to Default screen appears. 
LOCAL DEVICE 
  SET CONFIGURATION TO DEFAULT 
 ---------------------------- 
  NOTE:  After performing this operation all interfaces 
    will be set to NORMAL configuration. 
 0. Exit 
  1.  Reset to default configuration 
  Enter your choice: 1 
  Type 'reset' to confirm reset to default setting, ESC to cancel: 
 reset 
  All interfaces have been set to default! 
2. Type 1 to perform the reset to default configuration option. 
3. Type reset to confirm or press ESC to cancel your choice. 
4. Type 0 to exit the Set Configuration to Default screen. 