Specifications
Chapter 4 Supervisory Port Software Configuration  Optimux-XLT1 Installation and Operation Manual 
4-22  The Optimux-XLT1 Software Download
4.6  The Optimux-XLT1 Software Download 
➤  To download software: 
1. Type 3 in the Optimux-XLT1 Local Device screen. 
The Software Downloading screen appears. 
LOCAL DEVICE 
 SOFTWARE DOWNLOADING 
 -------------------- 
 0. Exit 
  1.  Download new software 
  Enter your choice: 
2. Type 1 to download new software. 
3. Type flash (in lower case only) when asked for the password. 
4. Press Enter. 
The Optimux-XLT1 resets itself and erases the flash memory. 
5.  Start the communication software. 
Depending on the terminal used, the popup screen differs. 
6.  Select the XMODEM protocol. 
7.  Enter the name and path of the software distribution file to be downloaded. 
8. Press Enter. 
The new software version is loaded to the flash memory. 
9.  Reset the unit by either turning it OFF and then ON or by pressing the RST 
push button on the unit's front panel. 
1.  Software download is not available for the remote device. 
2.  The downloading speed is determined by the baud rate set during the serial 
port configuration stage. To change the baud rate, refer to the 'Changing the 
Configuration of the Serial Port' section in this chapter. 
3.  When using Telnet for management, the Software Downloading option is not 
operational. 
Notes 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com