Specifications
Chapter 5 Troubleshooting & Diagnostics  Optimux-XLT1 Installation and Operation Manual 
5-2 Loop Connections
Table 5-1. Diagnostic Loops 
Loop Function 
T1 local  An incoming T1 signal is looped back to the T1 line. AIS is injected towards 
the T13 MUX. T1 local loop is set for all the ports belonging to a particular T1 
channel module. For HS modules, the loop can be set separately for each port 
belonging to a particular HS channel module. 
Fiber optic local  The outgoing fiber optic signal is looped back towards the T1 and Ethernet 
ports. AIS is injected in the outgoing fiber optic signal towards the link and 
propagated to the T1 signals in the remote Optimux-XLT1. 
T1 remote  The received T1 signal is looped back towards the link. AIS is injected in the 
T1 signal towards the T1 line. The T1 remote loop is set separately for each 
port belonging to a particular T1 channel module. 
Before setting the fiber optic local loop, set the clock source to INT and set the link 
redundancy to OFF. 
➤  To perform a T1 loop on Unit B: 
T1 loops can be made the same way on Unit B, with the terminal connected to 
Unit A, while choosing the remote option from the Main Menu of the Terminal 
Main Menu. 