Chapter 5 Troubleshooting & Diagnostics  Optimux-XLT1 Installation and Operation Manual 
5-4 Troubleshooting Instructions
Table 5-2. Troubleshooting Chart (Cont.) 
Trouble Symptoms  Probable Cause  Corrective Measures 
External problem  1.  Activate the fiber optic local loop on the 
Optimux-XLT1. 
2.  Check that all the SYNC LOSS and AIS indicators 
turn OFF, and that the equipment connected to the 
local channels receive their own transmissions. 
3.  If the indicators turn OFF, the problem is external. 
Troubleshoot the remote unit, and the fiber optic 
transmission path. 
All the units connected to 
a local Optimux-XLT1 do 
not receive the remote 
equipment. 
Defective Optimux-XLT1  Replace Optimux-XLT1 
Connection problem  Check the equipment connected to the local channel 
External problem  1.  Activate the port local loop on the Optimux-XLT1. 
2.  Check that any previously lit alarm indicators related 
to the channel turn OFF. 
3.  If the indicators turn OFF, the problem is external. 
Check the remote equipment. 
Only one of the units 
connected to a local 
Optimux-XLT1 does not 
receive from the remote 
equipment. 
Defective Optimux-XLT1  Replace Optimux-XLT1 
SYSTEM FLT indicator is 
ON 
Defective Optimux-XLT1.  Replace Optimux-XLT1 
Order from: Cutter Networks
Ph:727-398-5252/Fax:727-397-9610
www.bestdatasource.com