System information
User’s Manual  Chapter 4 Configuring Typical Applications 
Optimux-34 Ver. 2.81  Connecting Optimux-34 to the Management Station  4-9 
Table 4-3. Ethernet Port Parameters 
Parameter  Possible Values / Remarks 
Port Type  Fast Ethernet 
Read-Only 
Administrative Status  Up, Down 
Port status 
Selecting Down disables the remaining fields in this dialog box and any changed 
values of RW fields will not be sent the agent 
Relevant only for USER-ETH port 
User Name  Ethernet port name, up to 15 characters 
Connector Type  RJ-45 
Read-Only 
Port Status  Available: indicates that the link, light, or loopback is normal 
NotAvailable: indicates link loss, low light, or no loopback 
Read-Only 
Auto Negotiation  Enabled (checked) 
Disabled (unchecked) 
Read-Write 
Auto Negotiation Status  Configuring 
Completed 
Disabled 
Read-Only 
Flow Control  Enabled (checked) 
Disabled (unchecked) 
Read-Write 
Ethernet Mode  Half-Duplex 
Full-Duplex 
Note: 
This field is Read-Write only if Autonegotiation is disabled. 
Rate (Mbps) 
10 
100 
Note: 
This field is enabled only if Autonegotiation is disabled. 
Read-Write/Read-Only 
Rate Limitations (Mbps) 
For E1 channels: 
0
, 8, 16, 24, 32 
Rate limitation is configurable in multiples of 8Mbps. 
Relevant only for USER-ETH port 
USER-ETH speed is dependent in the rate limitation configured 