System information
Chapter 4 Configuring Typical Applications  User’s Manual 
4-12  Connecting Optimux-34 to the Management Station  Optimux-34 Ver. 2.81 
Figure 4-9. E1 Channel Parameters Dialog Box 
3.  Fill in the fields, as described in 
Table 4-5
. 
4. Click <Set> to implement the changes. 
If the User-ETH port has been configured to a rate > 0, the corresponding E1 
ports fields will be all Read-Only, and the <Set> button will be disabled. 
Table 4-5. E1 Port Parameters 
Parameter  Possible Values / Remarks 
Administrative Status  Up 
Down 
Read-Write (Read-Only, see 
Note
 above) 
Port Type  E1 
Read-Only 
User Name  The name for the interface as specified by the network manager. 
String of up to 15 characters 
Read-Write 
Connector Type  RJ-45 
Read-Only 
Interface Type  Unbalanced: 75 
Balanced: 120 
Read-Write 
Configuring Link Parameters 
You can view and configure parameters for the link ports (Link A or Link B). 
Note 