System information
Chapter 7 Fault Management  User’s Manual 
7-2  Handling Alarms and Traps  Optimux-34 Ver. 2.81 
Figure 7-1. Fault Menu – System Level 
List of Alarms and Events 
The Optimux-34 alarms are described in 
Table 7-1
. 
Table 7-1. Optimux-34 System Alarms 
Code  Message on terminal  Description  Severity 
1  PS A fail  No voltage in power supply A.  Major 
2  PS B fail  No voltage in power supply B.  Major 
3  Remote connection FAIL  A managment connection could not be established with 
the remote device. 
Major 
4 Redundancy not 
available 
Redundancy mode is set to AUTO or MANUAL but the 
second link is not installed. 
Major 
30  ETH Integrity fail  Failure in Ethernet management port 
integrity or in the fast Ethernet integrity. 
ETH-MNG 
ETH 
Major 
31  Signal Loss  Signal loss detected on uplinks or 
channels. 
E1 
LINK 
Major 
33  Rx AIS  Received AIS on the uplinks or the 
channels. 
E1 
LINK 
Minor 
The Optimux-34 events are described in 
Table 7-2
. 
Table 7-2. Optimux-34 Events 
Code Event  Description 
100 Software process failed
Failed to process software download. 
101  Buffer overflow  The event log buffer exceeded its maximum size and new events are 
written over the old ones. 
Viewing All Active Alarms 
The All Active Alarms command enables you to view all active alarms of the local 
and remote devices in the system. 
  To view all active alarms for the system: 
1.  In the RADview/TDM Optimux-34 window, select the system. 
2.  On the menu bar, click Fault > All Active Alarms. 