System information
Chapter 7 Fault Management  User’s Manual 
7-8  Handling Alarms and Traps  Optimux-34 Ver. 2.81 
Table 7-5. System Alarm Buffer Parameters 
Parameter  Possible Values / Remarks 
Code  The code number for the alarm that occurred 
1…120 
Read-Only 
Description  The description of the alarm corresponding to the specified code 
Read-Only 
Location  The device where the alarm ocurred 
Local 
Remote 
Read-Only 
Slot  Slot or link where the alarm occurred (if applicable) 
Link A 
Link B 
Read-Only 
Port  Indicates the port number this alarm refers to (if applicable) 
Link A 
Link B 
Channels 1-16 
MNG-ETH 
USER-ETH 
V.35 
Read-Only 
State  Indicates the alarm type 
Off: Disappearance of an alarm 
Event: Occurrence of an event 
Major: Appearance of a major problem 
Minor: Appearance of a minor problem 
Read-Only 
Date & Time  The date and time the alarm occurred 
Date format: yyyy-mm-dd 
Time format: hh:mm:ss 
Read-Only 
Clearing Alarms in the Alarm Buffer 
You can clear the alarm history log contained in the Optimux-34 Alarm Buffer. 
Selecting this entry will clear all the entries of the Alarm Buffer. 
  To clear all alarms in the Alarm Buffer: 
•  On the menu bar, click Fault > History Log > Clear. 
The History Log is cleared. No user confirmation is provided. 