Instructions

33
EN
22. Removing the belt in the event of unit failure
In the event that the RolloTron Standard unit fails and the
motor no longer runs, you can use the disengaging bracket
provided in order to fully remove the belt from the belt
winder unit, without the need for cutting it.
1.
Remove the mains plug from the socket.
2.
Dismantle the RolloTron Standard as previously dem-
onstrated on page 31.
3.
Release the drive with the help of the supplied disen-
gaging bracket.
ATTENTION
Hold on to the belt tightly, as otherwise the roller shut-
ters may slam shut.
A small amount of resistance must be overcome when
pressing.
4.
Maintain pressure on the disengaging bracket and pull
the belt out of the RolloTron Standard as far as possible.
5.
Release the belt from the fastening hook and pull it out
completely from the RolloTron Standard.
6.
Replace the disengaging bracket in its holder.
RolloTron
Standard
RolloTron
Standard
Plus
i
Drive release
Storage bay
Drive release