Instructions

67
EN
25. Technical Specications
i
Supply voltage: 230 V / 50 Hz; 230 V / 60 Hz
Nominal power: 70 W
Standby power: < 0.35 W
Nominal torque:
- RolloTron Comfort 10 Nm
- RolloTron Comfort Plus 14 Nm
Maximum speed:
- RolloTron Comfort 30 RPM.
- RolloTron Comfort Plus 24 RPM.
Maximum tractive force: see page 68 (tractive force diagrams)
Transient operation: 4 minutes (maximum running time)
Protection class: II
Protection type: IP20 (only for use in dry rooms)
Number of switching times: max. 28
Automated solar function
congurable range: 2,000 to 20,000 Lux
Automatic darkness control
congurable range: 2 to 50 Lux
Permissible ambient temperature: 0 - 40 °C
Mains connecting cable: 2 x 0.75 mm
2
(H03VVH2-F)
Dimensions: See page 14
Power reserve
The RolloTron Comfort has a power
reserve of approx. 8 hours.
Data retention subsequently to
power failure
All of the previously congured settings
will be retained subsequent to a power
outage, with the exception of the time
and date. As soon as the power supply is
restored, the opening and closing times
will be executed again.
Example:
Power failure from 22:30 - 6:30
hours.
The opening time has been set to
6:00 a.m.
Shortly after power is returned,
the switching command will be
executed and the roller shutters will
open.