Parallel connection of several motors (Fig.
m
)
Installation example
It is possible to connect numerous RADEMACHER tubular motors in parallel. The number of motors to be
connected in parallel is dependent on the capacity of the switchgear and circuit-breakers.
NOTE
It is not possible to control individual motors if the equipment is connected in parallel.
Configuring the end point for each individual motor
If several motors are connected in parallel, it is necessary to set both end points for each tubular motor, see
page 41. In order to do so, the set button for each tubular motor must be accessible.
IMPORTANT
For this reason, the set lead (j) for each individual tubular motor must be laid up to the respective junction
box. This means that the end points can be subsequently configured manually at any time.
Parallel connection with blinds switches or blinds buttons
RADEMACHER blinds switches or blinds buttons enable up to 5 motors to be switched in parallel.
Parallel connection with RADEMACHER controllers
Please refer to the technical data for the respective number of motors that can be connected in parallel.
Legend
(a) = Junction box
(b) = Switchgear e. g. 1-pole switch / button
(c) = Mains 230 V/50 Hz
Connection of an external switch (230V/50Hz) (Fig.
n
)
for subsequent adjusting the end point with the set line
IMPORTANT
After configuring the end points, disconnect the external switch again and connect the set lead (j) to
neutral (f), see figure l.
Legend
(a) = set button (7)
(b) = Controller (e.g. 1-pole switch / button)
(c) = Mains 230 V/50 Hz
(d) = Socket box
Pin assignment
(e) = PE green/yellow
(f) = N blue
(g) = L1 black
(h) = () black
(i) = () brown
(j) = white/grey (set lead)
(k) = external switch