What to do if... ?
i
...The set line is not available locally and the SET button on the tubular
motor is not accessible, however, the factory settings are to be loaded.
Solution
◆ In order to carry out this configuration, it is necessary to separately connect the two
control lines for up (▲) and down (▼) to phase (L).
◆ Either use an external button with two switching contacts or the commercially available
cord circuit set device (20).
◆ Always have the connection work carried out by a specialist
electrician and observe the safety information relating to the electri-
cal connection on page 37.
NOTE
Further information can be obtained from our Website at www.rademacher.de.
2.
1.
Press the down (▼) button and wait until the roller
shutters have travelled to the lower end point.
IMPORTANT
Keep holding down the down (▼) button even after
the lower end point has been reached.
Once the electrical connection is made, determine
the direction of rotation by means of briefly press-
ing the button.
3.
Additionally, briefly
press the up (▲) button
5 times for 0.5 seconds
each time and on the
sixth press, hold the
button down.
▲
▼
▲
▼
▲
4.
▲
▼
After a short time, the tubular motor acknowledges
by briefly running up and down.
The factory settings are now loaded.
Now release both buttons.5.
▲
▼
▲
▼
Re-adjust the end points if necessary, see page 41.
6.
7.
Switch off the mains power supply and reconfigure
the original connection in accordance with connection
diagram l on page 38.
1 x 0,5 s 1.
Hold down.6.
.
.
.
1 x 0,5 s 2.
1 x 0,5 s 3.
1 x 0,5 s 4.
1 x 0,5 s 5.
Brief description for loading the factory settings.