Instructions

4141
EN
. . .
2.
1.
End point setting
You can subsequently set or correct the end points of connected tubular motors using this function.
NOTE
The end point setting can only be adjusted when only one device (actuator) is registered within the
selected group ; if more than one component is registered within the selected group then the function
is blocked.
The end point setting can only be made for RADEMACHER electronic tubular motors from 2000 onwards
that are controlled with a correctly installed DuoFern actuator.
The end point setting cannot be adjusted for tubular motors connected in parallel.
The function is automatically cancelled if no button is pressed for approx. 30 seconds.
Select the desired DuoFern end device.
Activate the „end point setting” function.
In order to do so, press the disconnect” button twice in short
succession within one second (similar to the double-click of
a computer mouse).
2 x / second