User's Manual

27
Receiver Sensitivity
The following reflects the RF Data Rate and corresponding Receive Sensitivity with
frequency separation fixed at 64Khz intervals and the module is operating at 915 MHz.
RF
Data
Rate
Sensitivity
(Manchester
Mode)
RF
Data
Rate
Sensitivity
(Manchester
Mode)
600bps -110dBm 9600bps -102dBm
1200bps -108dBm 19.2Kbps -101dBm
2400bps -106dBm 38.4Kbps -99dBm
4800bps -103dBm 76.8Kbps -99dBm
MDK-2001 Development Board
This device is intended for usage in assisting developers during design implementation of
Radicom Research’s Wireless Modules into their embedded systems. It is not FCC
certified and should not be used for normal operational purposes.
CAUTION: To avoid damaging the module, always power off before
adding or removing the module.
Carefully remove the MDK2001 test fixture and module from the protective static bags.
Line up the module with the appropriate socket(s) on the MDK2001 and gently press the
module into the test fixture. Pin 18 is keyed to prevent plugging in improperly. Carefully
secure the provided antenna onto the module. Connect one end of the RS232 cable into
the rear 25 pin connector of the MDK2001 and the other end into the serial port of your
host equipment. With the power switch in the off position (down), plug in the power jack
to the back of the fixture. Now you can plug the AC adapter into any available 110-volt
outlet. Note: The 25 Pin connector on the side of the MDK2001 is for upgrading code.